Below are six problems that come up again and again for technicians in factories and commercial buildings across the Philippines, and the Fluke tools that help with each.
Below are six problems that come up again and again for technicians in factories and commercial buildings across the Philippines, and the Fluke tools that help with each.
A technician checks a circuit that should be dead and the meter shows voltage. Often it’s ghost voltage, a reading picked up from nearby energized wiring, and a standard high-impedance meter can’t tell the difference. The result is time spent chasing a problem that isn’t there or, worse, doubt about whether a circuit is safe.
This is where the Fluke 117 Electrician’s Multimeter can help. Its LoZ function uses low input impedance to help prevent false readings caused by ghost voltage, and AutoVolt picks AC or DC voltage automatically. It also has built-in non-contact voltage detection for a quick check before the test leads go on.
Measuring current with a standard multimeter means opening the circuit and putting the meter in series, and on a running production line that usually isn’t an option. So the check gets skipped, and an overloaded motor or circuit goes unnoticed until it trips.
A clamp meter measures current by clamping around a single conductor, with no need to disconnect anything. The Fluke 323 measures AC current up to 400 A and covers most everyday load checks. For larger conductors or tight cable bundles, the Fluke 376 reads up to 1000 A AC and DC, and its iFlex flexible probe extends the range to 2500 A AC. For more on choosing between the two types of meter, see our guide to digital multimeters and clamp meters.
Need current readings without stopping the line? Compare Fluke clamp meters and multimeters, with prices in pesos, VAT included.
Every time a test lead touches a live terminal inside a crowded panel, there’s a risk of a slip. And on routine checks, where the job is just confirming that voltage or current is present, handling test leads around live parts adds time as well as risk.
The Fluke T6-1000 PRO Electrical Tester uses FieldSense technology to measure AC voltage up to 1000 V and AC current up to 200 A through its open fork, without the test leads touching live parts. The conductor goes into the fork and both readings show on one screen.
Some of the hardest jobs are the faults that never show up while the technician is on site. A machine stops overnight, a breaker trips once a week, and by the next morning every measurement looks normal. Without a record of what happened at the time, it’s guesswork.
A power quality analyzer such as the Fluke 1777 can be left connected to record voltage and current over time, and it captures events such as dips, swells, interruptions, transients and inrush current. When the fault happens again, there’s data showing what the supply was doing at that moment. Our article on the top 10 problems the Fluke 1777 can diagnose goes through more examples.
A loose or corroded connection heats up long before it fails, but from the outside, the panel looks fine. By the time there’s a burning smell or a tripped breaker, the damage is done.
A thermal camera shows those hot spots during a normal inspection, and the images can be saved and shared with a supervisor or customer as proof of what was found. For technicians who want something small enough to carry every day, the Fluke iSee TC01A plugs into an Android phone and has a 256 × 192 infrared resolution. For dedicated handheld models, see the Fluke thermal camera range and our article on using thermal cameras on electrical systems
.
Want to see a Fluke tool working on a real job? Request a demo, and our team will show the functions that matter for the job.
Cables and motor windings lose insulation resistance slowly, through heat, moisture and age, and a standard multimeter won’t show it. The first sign is often a ground fault or a motor that won’t start.
An insulation tester applies a higher test voltage to find that weakness early. The Fluke 1507 offers test voltages of 50 V, 100 V, 250 V, 500 V and 1000 V, and it won’t run an insulation test if it detects more than 30 V on the circuit. It also discharges the circuit automatically after the test. We cover the method in more detail in how to detect insulation problems early with the Fluke 1507.
| Problem | Tool | Example |
|---|---|---|
| Ghost voltage and false readings | Multimeter with LoZ | Fluke 117 |
| Current checks without shutting down | Clamp meter | Fluke 323, Fluke 376 |
| Testing near live parts | Electrical tester with FieldSense | Fluke T6-1000 PRO |
| Faults that come and go | Power quality analyzer | Fluke 1777 |
| Hidden hot connections | Thermal camera | Fluke iSee TC01A |
| Insulation breakdown | Insulation tester | Fluke 1507 |
Not every technician needs every tool. Start with the problem that comes up most often on the job, and check the measurement range and safety rating of the exact model before buying.
Chomar Unitrade is an authorized Fluke distributor in the Philippines. Tell us the problem that keeps coming up, and we’ll recommend the right tool. Order online, or contact us on 02-7949 2618 or sales@chomarunitrade.com for a quotation.